Text Box: Wine Guardian Specifications

Phone: 845-278-5281

Fax: 845-207-3060

E-mail: sales@winecareconcepts.com

 

Model Number                            WG025               WG050               WG088               WG200

___________________________________________________________________________________

 

Dimensions (w  x d x h)                       35”x14”x14”         39”x22”x14”         39”x22”x14”         43”x22”x18”

 

Performance

Nominal Tonnage (tons)                      ¼                              ½                              1                                2

Nominal Compressor (hp)                   1/3                           ½                              1                                2.5

Net Cooling Capacity* (btu)                              

                                  @ 70F ambient     3300                        5600                        8400                        16200

                                  @ 80F ambient     3000                        5300                        7800                        15200

                                  @90F ambient      2800                        4850                        7300                        14100

Controls                   Room-mounted non-programmable thermostat (+/- 2F).

 

Evaporator Section

Fan Motor Size (watts)                        75                             100                           195                           240

Rated Air Flow (cfm)                             235                           435                           510                           740

Air Flow w/25’ flex duct                      207                           400                           485                           715

 

Condenser Section

Fan Size (watts)                                      75                             100                           195                           240

Rated Air Flow (cfm)                             253                           400                           500                           750

Air Flow w/25’ flex duct                      220                           365                           475                           720

 

Heating (watts/btu)                              1000/3413          1000/3413          2000/6826          2000/6826

Temperature Rise (deg F)                   13.5                         8.6                            12                             8.1

 

Humidifier*

Gal./day (supply water @ 60F)         1.6           *- usage rate also affected by exterior climate,

Gal./day (supply water @ 90)           3.5                vapor barrier, water pressure in supply line.

Gal./day (supply water at 120F)      5.1

 

Electrical Requirements    

Power Requirements (V/P/H)           115/1/60              115/1/60              230/1/60              230/1/60

Current Draw (cooling mode)            8.6a                          11.9a                       9.0a                          15a

Current Draw (heating mode)           9.4a                          9.6a                          9.6                            10

Minimum Circuit Size (amps)            15                             15                             15                             20

Optional Low Ambient (amps)          0.4                            0.4                            0.2                            0.2

Optional Humidifier (amps)               0.3                            0.3                            0.2                            0.2

Cabinet

Construction                                            .063 Aluminum

Finish                                                         Black, powder coat, corrosion inhibiting

Weight (lbs)                                             80                             125                           145                           195

 

*- Net Cooling Capacity at cellar temperature of 55F and 60% RH and at rated air flow.

ALL RATINGS AT SEA LEVEL; reduced capacity at altitude; inquire for elevations over 2,500 feet.

 

 

 